Description
The MedixDR features state of the art 2D narrow-angle fan beam technology based on a 256 element detector, which provides excellent image quality as well as fast exam times, making it the ideal solution for all types of practices.
The MedixDR is powered by Eazix, Medilink’s powerful software platform, designed with usability and efficiency in mind. Because of the reduced magnification and distortion effects (parallax errors) inherent to wide-angle fan beam densitometry, the 2D narrow-angle fan beam technology in the MedixDR ensures that area, BMD and geometric measurements are always accurate.
MedixDR Features
- Uses proven Narrow-Angle 2D Fan Beam technology
- The 256 element detector ensures excellent image quality
- Full size DEXA unit capable of whole body composition and regional bone density scans
- Quick scan times of 11 seconds for hip and 15 seconds for AP spine when using Fast Mode
- VAT – Visceral Adipose Tissue Analysis
Measure for Bone Mineral Density (BMD), Bone Mineral Content (BMC), T-score, Z-score and Area.
- Bone Mineral Content, Mass & Area
- Muscle – Density, Mass & Area
- Fat – Density, Mass & Area
- Fat %, Lean %, Bone %
- Andriod/Gynoid Ratio
- VAT – Visceral Adipose Tissue
- Fat Mass Index
- Basal Metabolic Rate
- Colour mapping image for visualising fat density/areas
- Hip Axis Length (HAL)
- Femoral Neck Axis Length (FNAL)
- Intertrochanter to Femoral Head Centre Distance (IH)
- Femoral Axis versus Neck Axis Angle (FNA)
Custom ROI selection
The custom ROI (region of interest) option allows calculation of BMD from any selected site. Regions can be colour coded and measured for consistency between scans.
FRAX® Tool
Evaluate the 10 year probability of osteoporotic fractures and intervention thresholds with the FRAX® tool.
DVA provides a low dose, lateral image to view all the vertebrae of the spine. Deformation or compression is precisely diagnosed, measured and classified. This analysis can be either automatic using the Genant’s semi-quantitative classification, or manual using the Genant’s visual classification.
Morphometric tools help measure and evaluate significant predictors of fracture in all available scanning functions and aid in therapeutic monitoring. Easily print-out patient results to guarantee therapeutic monitoring
The Paediatric option makes it possible to evaluate the BMD, BMC, Area and Body composition in children. Users can also calculate Z-score and compare skeletal age with this function.
With the Orthopaedic option, Easix makes it possible to measure BMD around the prosthesis, enabling smart implant management. The Orthopaedic option also enables measurement of the hand, forearm, elbow, shoulder, spine, hip, AP knee, lateral knee and feet. Automatic detection of ROI is available for hip, knee and lateral knee exams.
Two exams (hip and spine) can be performed in one single operation thus improving workflow and comfort for both patients and users.